uplinkfast, backbonefast

uplinkfast

Cata2950_2#sho spanning-tree uplinkfast

UplinkFast is enabled

02:45:18: %SPANTREE_FAST-7-PORT_FWD_UPLINK: VLAN0020 FastEthernet0/11 moved to Forwarding (UplinkFast).


Station update rate set to 150 packets/sec.

UplinkFast statistics
-----------------------
Number of transitions via uplinkFast (all VLANs)            : 1
Number of proxy multicast addresses transmitted (all VLANs) : 4

Name                 Interface List
-------------------- ------------------------------------
VLAN0001             Fa0/24(fwd)
VLAN0010             Fa0/24(fwd)
VLAN0020             Fa0/11(fwd)
VLAN0030             Fa0/24(fwd)
backbonefast
uplinkfastは即座にFWDになり、メッセージも表示されるが、backbonefastはLIS→LRNを経る。だが、本来ならBPDU消失を検知してからこの移行を実施するので、 それを省略することによりより速い切り替えをおこなう。
Cata2950_2#sho spanning-tree backbonefast
BackboneFast is enabled

BackboneFast statistics
-----------------------
Number of transition via backboneFast (all VLANs)           : 1
Number of inferior BPDUs received (all VLANs)               : 1
Number of RLQ request PDUs received (all VLANs)             : 0
Number of RLQ response PDUs received (all VLANs)            : 1
Number of RLQ request PDUs sent (all VLANs)                 : 1
Number of RLQ response PDUs sent (all VLANs)                : 0

Cata2950_2#sho sp vl 20

VLAN0020
  Spanning tree enabled protocol ieee
  Root ID    Priority    32788
             Address     000b.fdb9.a680
             Cost        19
             Port        12 (FastEthernet0/12)
             Hello Time   2 sec  Max Age 20 sec  Forward Delay 15 sec

  Bridge ID  Priority    32788  (priority 32768 sys-id-ext 20)
             Address     0016.9da0.4ec0
             Hello Time   2 sec  Max Age 20 sec  Forward Delay 15 sec
             Aging Time 15

Interface        Role Sts Cost      Prio.Nbr Type
---------------- ---- --- --------- -------- --------------------------------
Fa0/10           Altn BLK 19        128.10   P2p
Fa0/12           Root FWD 19        128.12   P2p
Fa0/16           Desg BKN*19        128.16   P2p *LOOP_Inc


Cata2950_2#sho spanning-tree inconsistentports

Name                 Interface              Inconsistency
-------------------- ---------------------- ------------------
VLAN0020             FastEthernet0/16       Loop Inconsistent
loop guard
Cata3550#sho udld gigabitEthernet 0/1

Interface Gi0/1
---
Port enable administrative configuration setting: Follows device default
Port enable operational state: Enabled
Current bidirectional state: Bidirectional
Current operational state: Advertisement - Single neighbor detected
Message interval: 15
Time out interval: 5

    Entry 1
    ---
    Expiration time: 41
    Device ID: 1
    Current neighbor state: Bidirectional
    Device name: CAT0732Z28X
    Port ID: Gi0/1
    Neighbor echo 1 device: CAT0704Z0SX
    Neighbor echo 1 port: Gi0/1

    Message interval: 5
    CDP Device name: SW2